Study of potential leakage on several stressed fittings for hydrogen pressures up to 700 bar

Abstract

In order to improve risk analyses and influence the design of the future hydrogen systems, an experimental study on leaks qualification and quantification was performed. In H2 energy applications, fittings appear as a significant leakage potential and subsequently explosion and flame hazards. Thus, as part of the 'Horizon Hydrogène Energie' French program [1], four kinds of commercial fittings usually employed on H2 systems were tested thanks to a new high pressure test bench - designed, setup and operated by INERIS - allowing experiments to be conducted for H2 pressures up to 700 bar. The fittings underwent defined stresses representative of H2 systems lifetime and beyond. The associated leaks - when existing - are characterized in terms of flow rate.
No file

Dates and versions

ineris-00970868 , version 1 (02-04-2014)

Identifiers

Cite

D. Houssin-Agbomson, Didier Jamois, Christophe Proust, Jérôme Daubech, S. Ruban, et al.. Study of potential leakage on several stressed fittings for hydrogen pressures up to 700 bar. 4. International Conference on Hydrogen Safety (ICHS 2011), Sep 2011, San Francisco, United States. pp.NC. ⟨ineris-00970868⟩